| Specifications | VIPRION 4800 Chassis | VIPRION 4480 Chassis |
|---|---|---|
| Power Supply | One to four 200 VAC to 240 VAC (2600W) auto ranging (80+ Gold Efficiency)(2 power supplies included) 18A per input (max) DC power (option) One to four 2600W -44 to -72 VDC 80A per input maximum per supply Note: Please refer to the VIPRION 4800 Platform Guide for the latest specific AC power ratings. |
One to four 90 VAC (1200W) to 240 VAC (2000W) auto ranging20A per input line (max) DC power (option) One to four 1200W -36 to -72 VDC 10 to 40A maximum per supply Note: Please refer to the VIPRION 4480 Platform Guide for the latest specific AC power ratings |
| Dimensions | 27.8” (70.6 cm) H x 17.4” (44.2 cm) W x 21.25” (54.0 cm) D 16U industry standard rack-mount chassis | 12.2” (30.9 cm) H x 17.4” (44.2 cm) W x 21” (53.3 cm) D 7U industry standard rack-mount chassis |
| Weight | 126 lbs. (57.2 kg) (2 power supplies, 2 fan trays, 8 blanks) | 87 lbs. (39.5 kg) (4 power supplies, 1 fan tray, 3 blanks) |
| Operating Temperature | 32° to 104° F (0° to 40° C) | 32° to 104° F (0° to 40° C) |
| Safety Agency / Approval | UL 60950 (UL1950-3)CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950 |
UL 60950 (UL1950-3)CSA-C22.2 No. 60950-00(bi-national standard with UL 60950) CB test certification to IEC 950 EN 60950 |
| Certifications / Susceptibility Standards | EN55022 1998 Class A | EN55022 1998 Class A |
| Standards | EN55024 1998 Class A FCC Part 15B Class A VCCI Class A |
EN55024 1998 Class A FCC Part 15B Class A VCCI Class A NEBS Certified |
| Relative Humidity | 5 to 85% at 104° F (40° C) | 5 to 85% at 104° F (40° C) |
| Supported Blades | B4300 or B4450 | B4300 or B4450 |
| Maximum Number of Blades | 8 Blades | 4 Blades |
Legacy VIPRION 4400 Chassis and 4200N Blade
Before the VIPRION® 4480 and 4800, F5 shipped the original VIPRION 4400 chassis (J100): a 7 RU chassis holding up to 4 blades (B4100, B4200 and B4300), with four 90–240 VAC auto-ranging power supplies and an optional 36–72 VDC supply. The 4200 (A107), 4200N (A111) and 4300 (A108) blades in a 4400 chassis support BIG-IP 10.1.0 through 12.0.0; in a 4480 chassis the 4200N supports BIG-IP 10.1.0 through 12.1.2. The VIPRION B4100 blade reached End of Technical Support (EoTS) on June 30, 2019. For legacy VIPRION 4400 or 4200N replacement options, contact us.
Compatible VIPRION BIG-IP Software Version Matrix for 4480 – 4800 Chassis and Cards
For a complete list of all BIG-IP release notes and release dates, please follow the link.
For a table with all compatible hardware and software versions, please follow the link.
The final version of BIG-IP available for the VIPRION B4200 blade in a VIPRION 4480 Chassis is 12.0.0.
| Hardware | Compatible software versions | Lifecycle note | AOM | EUD | |||||
|---|---|---|---|---|---|---|---|---|---|
| Chassis/Type | Blade/Type | ||||||||
| 17.x | 16.x | 15.x | 14.x | 13.x | |||||
| 4480/J102 | 4300/A108 | None | None | 15.0.0 – 15.1.2 | 14.0.0 – 14.1.4 | 13.0.0 – 13.1.3 | Blade – EoNSS1 / EoSS2 | N/A | CF.15.3.0 |
| 4340N/A110 | None | 16.0.0 – 16.0.1 | 15.0.0 – 15.1.3 | 14.0.0 – 14.1.4 | 13.0.0 – 13.1.4 | Blade – EoNSS1 / EoSS2 | N/A | CF.15.3.0 | |
| 4450/A114 | 17.0.0 – 17.1.1 | 16.0.0 – 16.1.4 | 15.0.0 – 15.1.10 | 14.0.0 – 14.1.5 | 13.0.0 – 13.1.5 | N/A | N/A | CF.15.3.0 | |
| 4800/S100 | 4300/A108 | None | None | 15.0.0 – 15.1.2 | 14.0.0 – 14.1.4 | 13.0.0 – 13.1.3 | Blade – EoNSS1 / EoSS2 | N/A | CF.15.3.0 |
| 4340N/A110 | None | 16.0.0 – 16.0.1 | 15.0.0 – 15.1.3 | 14.0.0 – 14.1.4 | 13.0.0 – 13.1.4 | Blade – EoNSS1 / EoSS2 | N/A | CF.15.3.0 | |
| 4450/A114 | 17.0.0 – 17.1.1 | 16.0.0 – 16.1.4 | 15.0.0 – 15.1.10 | 14.0.0 – 14.1.5 | 13.0.0 – 13.1.5 | N/A | N/A | CF.15.3.0 | |